{"id":2872,"date":"2015-12-14T12:21:14","date_gmt":"2015-12-14T16:51:14","guid":{"rendered":"https:\/\/www.hidrasoftware.com\/en\/?p=2872"},"modified":"2020-11-25T04:48:31","modified_gmt":"2020-11-25T09:18:31","slug":"the-dren-urbas-2-0-sewer-pipes-tab","status":"publish","type":"post","link":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/","title":{"rendered":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab"},"content":{"rendered":"<p><span lang=\"EN-US\">Now that we have made the surface system calculations, as we saw in the <a href=\"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-surface-drainage-tab\/\">previous tutorial of this series<\/a>, it <b>is time to perform the storm sewer network\u2019s design, which will allow the collection and conveyance of the drainage inlet\u00b4s intercepted rainfall flow<\/b> to the network\u2019s outflow point.<\/span><\/p>\n<p><span lang=\"EN-US\">In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.<\/span><\/p>\n<p><span lang=\"EN-US\">These built-in features and tools can be found at the SEWER PIPES tab of the new version, which will be introduced to you in the next video.<\/span><\/p>\n<div class=\"su-note\"  style=\"border-color:#e5c971;border-radius:3px;-moz-border-radius:3px;-webkit-border-radius:3px;\"><div class=\"su-note-inner su-u-clearfix su-u-trim\" style=\"background-color:#FFE38B;border-color:#ffffff;color:#333333;border-radius:3px;-moz-border-radius:3px;-webkit-border-radius:3px;\">\n<p><span lang=\"EN-US\">Since the properties and functionality of the tools on this tab are shared with CLOACAS software, you will see, in the transcript below the video, links to tutorials that will explain in detail how to use them.<\/span><\/p>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-fancy su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>Transcription<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<p><b><span lang=\"EN-US\">The Sewer Pipes tab<\/span><\/b><span lang=\"EN-US\"> has, essentially, the same characteristics as the Surface Drainage.<\/span><\/p>\n<p><span lang=\"EN-US\">In the new version of our <a href=\"https:\/\/www.hidrasoftware.com\/en\/the-stormwater-urban-drainage-design-software\/\">storm sewer design software<\/a>, <b>you may have one or more storm sewer networks<\/b>, each having a single discharge point.<\/span><\/p>\n<p><span lang=\"EN-US\">The original idea of \u200b\u200bthe software is that the stormwater flow that is conveyed by this pipe sewers system, is strictly provided only by the surface system\u2019s drainage inlets.<\/span><\/p>\n<p><span lang=\"EN-US\">That is, <b>the Inlet\u00b4s intercepted flow, calculated in the surface drainage system\u2019s design, will be discharged into the nearest sewer network\u2019s manhole<\/b> so as to be able to establish the stormwater design flow corresponding to each pipe section, according to the network topology.<\/span><\/p>\n<p><span lang=\"EN-US\">In this new version, in addition to the above<b>, it is also possible to omit the surface system\u2019s design or definition<\/b> and perform the analysis, assigning affluent areas or sub basins to the sewer network\u2019s manholes.<\/span><\/p>\n<p><span lang=\"EN-US\">This is as to <b>assume that, close to each manhole with one or more assigned sub basins, there is a drainage inlets that intercept one hundred percent of the surface flow<\/b> that could generate such sub basins.<\/span><\/p>\n<p><span lang=\"EN-US\">Under this analysis mode, you can<b> <\/b>certainly<b> ignore the whole thing related to streets, channels, and drainage inlets,<\/b> as we saw in the last video of this series, <b>and limit yourself to assigning each sub basin, in the urban area under study, to the nearest manhole.<\/b><\/span><\/p>\n<p><span lang=\"EN-US\">To do so, <b>you must select the automatically assign areas to Manholes<\/b> in the General Project\u00b4s Settings, so that the software does most of the work, searching for the closest manhole to the centroid of each polygon or sub basin.<\/span><\/p>\n<p><span lang=\"EN-US\">Of course, when you perform the calculation of the current sewer network, <b>you will see that assignment lines are now focused to the manholes,<\/b> instead of to the street sections. And, when you review the properties of any of them, you will also see that the sub basins have been automatically assigned.<\/span><\/p>\n<p><span lang=\"EN-US\">Of course, as we saw in the previous video, <b>you can manually create your own user defined sub basins<\/b>, that is, they will not be drawn in the drawing area.<\/span><\/p>\n<p><span lang=\"EN-US\">And, in case you want to override the automatic assignment and manually assign some of those drawn sub basins to one of the manholes, you can select it and, from its Properties dialog, <b>activate the manual assignment check box in order to select any manhole in the Project.<\/b><\/span><\/p>\n<p><span lang=\"EN-US\">Thus, let\u2019s know the tools we have provided in this tab.<\/span><\/p>\n<p><span lang=\"EN-US\">The options for creating one or more stormwater collection systems are in the Sewer Networks panel, each made up of a series of manholes and sewer pipe sections and, as we said, a single discharge point.<\/span><\/p>\n<p><span lang=\"EN-US\">This dialog is the same as the surface system\u2019s one; you must specify its unique name, and a prefix used to labels\u2019 automatic creation as well as a number or initial counter for them.<\/span><\/p>\n<p><span lang=\"EN-US\">Remember that, <b>for creating, editing, calculation, and design purposes, everything you do will be effective only on the sewer network you have here as current<\/b>, showing data and results for it at the tables in the respective tab.<\/span><\/p>\n<p><span lang=\"EN-US\">The <b>Manholes and Sewer Pipes panels<\/b> offer options to create them in the drawing area, and, in the case of the buttons here at the right of each panel, will allow you to move the position of each manhole or pipe section in the respective table.<\/span><\/p>\n<p><span lang=\"EN-US\">Like all objects in the stormwater urban drainage system that you create in the software, you will see that it is possible, once you select a manhole or pipe section in the drawing area and click the right mouse button, to <b>show its respective properties dialog<\/b>.<\/span><\/p>\n<p><span lang=\"EN-US\">For manholes, note that the known <b>option for automatic elevation assigning from elevations points is available<\/b>, and <b>clicking the sub basins button<\/b> gives you access to the list of areas that have been assigned to the manhole, if needed.<\/span><\/p>\n<p><span lang=\"EN-US\">Additionally, in case you want <b>to include external flows whose origin is different to the hydrological one in the sewer network<\/b>, you have the <b>inflow field<\/b> to enter the respective value in correspondent manholes.<\/span><\/p>\n<p><span lang=\"EN-US\">In the case of <b>stormwater sewer pipe sections<\/b>, you will see that the properties dialog is rather a design dialog, where you can modify the geometric parameters to establish the hydraulic values \u200b\u200brequired in your design.<\/span><\/p>\n<p><span lang=\"EN-US\">This <b>sewer pipes editor<\/b>, with slight differences, is the same that has been already incorporated in the first version of our program for the calculation and design of sanitary sewer systems, CLOACAS.<\/span><\/p>\n<p><a href=\"https:\/\/www.hidrasoftware.com\/en\/the-sewer-pipes-editor-in-cloacas-the-sanitary-design-software\/\"><b>Click here to See the Tutorial<\/b><\/a><\/p>\n<p><span lang=\"EN-US\">On the other hand, a very important aspect, not only in terms of the generation of longitudinal profiles as part of the design results but also for the purposes of the automatic design features the software offers, <b>is that, for each sewer network you create, defining the sub networks that make it up is required.<\/b><\/span><\/p>\n<p><span lang=\"EN-US\">And for that, the option is on the <b>left button at the panel Sub Networks<\/b>.<\/span><\/p>\n<p><span lang=\"EN-US\">As you can see, in this stormwater sewer network, we have defined five sub networks.<\/span><\/p>\n<p><b><span lang=\"EN-US\">A main sewer<\/span><\/b><span lang=\"EN-US\">, which is directly affluent to the manhole selected as the network\u2019s discharge point.<\/span><\/p>\n<p><b><span lang=\"EN-US\">And four sewer lines or secondary sub networks<\/span><\/b><span lang=\"EN-US\"> that are tributaries to the main sewer.<\/span><\/p>\n<p><span lang=\"EN-US\">Note that the definition of each of these sub networks starts by placing on the list of assigned pipe sections, the one that is the most upstream within that sub network.<\/span><\/p>\n<p><span lang=\"EN-US\">This is what we call the sub network <b>starting sewer pipe<\/b>. From here you go to assigning pipe sections along the flow path to finish specifying the lower one, that is, the section whose downstream manhole is the point at which the sub network discharges, either the manhole defined as the network\u2019s discharge point for the main collector or any other manhole, in a different sub network, in the case of secondary and higher order sewers.<\/span><\/p>\n<p><span lang=\"EN-US\">Once more, this feature is similar to the one that already exists in our CLOACAS Software<\/span><\/p>\n<p><a href=\"https:\/\/www.hidrasoftware.com\/en\/defining-sub-networks-in-a-sanitary-sewer-network-created-with-cloacas-software\/\"><b>Click Here to See the Tutorial<\/b><\/a><\/p>\n<p>As previously noted, <strong>this will be used in the sewer network\u2019s automatic design, but it also serves so that, when you go to Results tab and ask for longitudinal profiles<\/strong>, you have all the components of each network separated according to their order in the whole system.<\/p>\n<p><strong>The button at the right of Sub networks panel<\/strong> allows you to automatically sort data in the Sewer Pipes tab\u2019s tables, depending on the division into sub networks that has previously established.<\/p>\n<p>And finally, there are the options of calculation and design for the current stormwater sewers network.<\/p>\n<p>When we speak about <strong>the Calculation button, we must be clear that it is the option that allows you to calculate the hydraulic parameters<\/strong> of the current sewer pipes network.<\/p>\n<p>That is, the <strong>software will not perform for you any geometrical data modification<\/strong>.<\/p>\n<p>So, in cases where sewer pipe sections exist with null or negative longitudinal slopes, or any other data that invalidates or turns the calculation impossible, the software will warn you that it is not possible to continue to perform the calculation.<\/p>\n<p>The idea behind this button is, to say, the sewer network\u2019s revision.<\/p>\n<p>Now, if your intention is precisely to make the design of the storm sewer system, you have three options within the <strong>Design button:<\/strong><\/p>\n<ul>\n<li>The first option is focused on <strong>calculating, for each sewer pipe section and depending on conveyed stormwater flows, the required longitudinal slope<\/strong>, and with it, the invert elevations necessary to fulfill conditions such as minimum pipe coverage or minimum slope of the pipe you have specified in the project\u2019s general settings.<\/li>\n<\/ul>\n<p><strong>In this design option, it is assumed that the pipe sections\u2019 diameters are adequate and\u00a0 therefore will not be changed.<\/strong><\/p>\n<ul>\n<li><strong>The second design option focuses on determining not only the required diameter for each sewer pipe section<\/strong>, always depending on the design parameters you have specified, but also <strong>seeks to determine, if applicable, the minimum longitudinal slope possible to minimize excavation costs.<\/strong><\/li>\n<\/ul>\n<p>Where possible, as a first choice, the software will <strong>try to assign to each pipe section the same longitudinal slope that the ground has in its alignment<\/strong>.<\/p>\n<p>In cases where the ground\u2019s longitudinal slope is not favorable or does not meet the design requirements, the minimum slope you have specified in the project\u2019s settings will be assigned, and if it still does not fulfill the design\u2019s constraints, the software will start to increase its value until compliance is achieved.<\/p>\n<ul>\n<li>Finally, you have the option which unconditionally <strong>respects existing pipe sections\u2019 longitudinal slopes and, from them, determines the diameter of each section<\/strong>.<\/li>\n<\/ul>\n<p>Regarding the latter two automatic design options, and reviewing the pipes libraries we have defined in this project, <strong>keep in mind that the diameters to be used in the design are those you have specified in the pipe section\u2019s assigned pipes library<\/strong>.<\/p>\n<p>So, for example, the pipe sections that have this pipes library assigned, may only have a diameter between 45 and 150 centimeters as a result of the automatic design.<\/p>\n<p>In case of considering that, in the automatic design, resulting diameters should be of greater or lesser magnitude,\u00a0 is a must to add more rows to the pipes library in question, in order to increase, so to speak, the search range of automatic design.<\/p>\n<p>As you can see, DREN-URBA is now a comprehensive program, with which it is practically unnecessary to devote too much time to completing the stormwater drainage system design.<\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.<\/p>\n","protected":false},"author":1,"featured_media":2873,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[154],"tags":[155,90,204,157,202,203],"class_list":["post-2872","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-urban-drainage-software","tag-drainage-design-software","tag-drainage-system-design","tag-storm-sewer-pipe","tag-stormwater-design","tag-stormwater-design-software","tag-urban-runoff","post-wrapper","thrv_wrapper"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5 - aioseo.com -->\n\t<meta name=\"description\" content=\"In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.\" \/>\n\t<meta name=\"robots\" content=\"max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"adminHS\"\/>\n\t<meta name=\"keywords\" content=\"drainage design software,stormwater design software,urban runoff,drainage system design,stormwater design,storm sewer pipe\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#article\",\"name\":\"The DREN-URBA\\u2019S 2.0 Sewer Pipes Tab | HidraSoftware\",\"headline\":\"The DREN-URBA\\u2019S 2.0 Sewer Pipes Tab\",\"author\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/author\\\/as_hid-ad\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/SewerPipesTab.png\",\"width\":1565,\"height\":483},\"datePublished\":\"2015-12-14T12:21:14+00:00\",\"dateModified\":\"2020-11-25T04:48:31+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#webpage\"},\"articleSection\":\"Urban Drainage Software, drainage design software, drainage system design, storm sewer pipe, stormwater design, stormwater design software, urban runoff\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#listItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/category\\\/urban-drainage-software\\\/#listItem\",\"name\":\"Urban Drainage Software\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/category\\\/urban-drainage-software\\\/#listItem\",\"position\":2,\"name\":\"Urban Drainage Software\",\"item\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/category\\\/urban-drainage-software\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#listItem\",\"name\":\"The DREN-URBA\\u2019S 2.0 Sewer Pipes Tab\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#listItem\",\"name\":\"Inicio\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#listItem\",\"position\":3,\"name\":\"The DREN-URBA\\u2019S 2.0 Sewer Pipes Tab\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/category\\\/urban-drainage-software\\\/#listItem\",\"name\":\"Urban Drainage Software\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#organization\",\"name\":\"HidraSoftware\",\"description\":\"Tutoriales , Art\\u00edculos y Novedades Relacionados con el Uso de Nuestros Programas\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/Logo-Hidra-h80.png\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#organizationLogo\",\"width\":242,\"height\":80},\"image\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/author\\\/as_hid-ad\\\/#author\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/author\\\/as_hid-ad\\\/\",\"name\":\"adminHS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a5f65c7aef12ce489c166cc63dcb2e245c7de0236f09ba154c8e7f7874ac52b2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"adminHS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#webpage\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/\",\"name\":\"The DREN-URBA\\u2019S 2.0 Sewer Pipes Tab | HidraSoftware\",\"description\":\"In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/author\\\/as_hid-ad\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/author\\\/as_hid-ad\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/SewerPipesTab.png\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#mainImage\",\"width\":1565,\"height\":483},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/the-dren-urbas-2-0-sewer-pipes-tab\\\/#mainImage\"},\"datePublished\":\"2015-12-14T12:21:14+00:00\",\"dateModified\":\"2020-11-25T04:48:31+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/\",\"name\":\"HidraSoftware\",\"description\":\"Tutoriales , Art\\u00edculos y Novedades Relacionados con el Uso de Nuestros Programas\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.hidrasoftware.com\\\/en\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab | HidraSoftware","description":"In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.","canonical_url":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/","robots":"max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"drainage design software,stormwater design software,urban runoff,drainage system design,stormwater design,storm sewer pipe","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#article","name":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab | HidraSoftware","headline":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab","author":{"@id":"https:\/\/www.hidrasoftware.com\/en\/author\/as_hid-ad\/#author"},"publisher":{"@id":"https:\/\/www.hidrasoftware.com\/en\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/12\/SewerPipesTab.png","width":1565,"height":483},"datePublished":"2015-12-14T12:21:14+00:00","dateModified":"2020-11-25T04:48:31+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#webpage"},"isPartOf":{"@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#webpage"},"articleSection":"Urban Drainage Software, drainage design software, drainage system design, storm sewer pipe, stormwater design, stormwater design software, urban runoff"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/#listItem","position":1,"name":"Inicio","item":"https:\/\/www.hidrasoftware.com\/en\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/category\/urban-drainage-software\/#listItem","name":"Urban Drainage Software"}},{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/category\/urban-drainage-software\/#listItem","position":2,"name":"Urban Drainage Software","item":"https:\/\/www.hidrasoftware.com\/en\/category\/urban-drainage-software\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#listItem","name":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/#listItem","name":"Inicio"}},{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#listItem","position":3,"name":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab","previousItem":{"@type":"ListItem","@id":"https:\/\/www.hidrasoftware.com\/en\/category\/urban-drainage-software\/#listItem","name":"Urban Drainage Software"}}]},{"@type":"Organization","@id":"https:\/\/www.hidrasoftware.com\/en\/#organization","name":"HidraSoftware","description":"Tutoriales , Art\u00edculos y Novedades Relacionados con el Uso de Nuestros Programas","url":"https:\/\/www.hidrasoftware.com\/en\/","logo":{"@type":"ImageObject","url":"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/01\/Logo-Hidra-h80.png","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#organizationLogo","width":242,"height":80},"image":{"@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.hidrasoftware.com\/en\/author\/as_hid-ad\/#author","url":"https:\/\/www.hidrasoftware.com\/en\/author\/as_hid-ad\/","name":"adminHS","image":{"@type":"ImageObject","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/a5f65c7aef12ce489c166cc63dcb2e245c7de0236f09ba154c8e7f7874ac52b2?s=96&d=mm&r=g","width":96,"height":96,"caption":"adminHS"}},{"@type":"WebPage","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#webpage","url":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/","name":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab | HidraSoftware","description":"In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.hidrasoftware.com\/en\/#website"},"breadcrumb":{"@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#breadcrumblist"},"author":{"@id":"https:\/\/www.hidrasoftware.com\/en\/author\/as_hid-ad\/#author"},"creator":{"@id":"https:\/\/www.hidrasoftware.com\/en\/author\/as_hid-ad\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/12\/SewerPipesTab.png","@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#mainImage","width":1565,"height":483},"primaryImageOfPage":{"@id":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/#mainImage"},"datePublished":"2015-12-14T12:21:14+00:00","dateModified":"2020-11-25T04:48:31+00:00"},{"@type":"WebSite","@id":"https:\/\/www.hidrasoftware.com\/en\/#website","url":"https:\/\/www.hidrasoftware.com\/en\/","name":"HidraSoftware","description":"Tutoriales , Art\u00edculos y Novedades Relacionados con el Uso de Nuestros Programas","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.hidrasoftware.com\/en\/#organization"}}]}},"aioseo_meta_data":{"post_id":"2872","title":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab | #site_title","description":"In the new version of DREN-URBA, the 2.0, we have incorporated the same creation features of the storm sewer network\u2019s objects: Manholes and pipes as well as the automatic design features that we had included in our software for sanitary sewers network design: CLOACAS.","keywords":[{"label":"drainage design software","value":"drainage design software"},{"label":"stormwater design software","value":"stormwater design software"},{"label":"urban runoff","value":"urban runoff"},{"label":"drainage system design","value":"drainage system design"},{"label":"stormwater design","value":"stormwater design"},{"label":"storm sewer pipe","value":"storm sewer pipe"}],"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":null,"schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2020-12-24 17:51:34","updated":"2022-09-14 00:46:37","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.hidrasoftware.com\/en\/\" title=\"Inicio\">Inicio<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.hidrasoftware.com\/en\/category\/urban-drainage-software\/\" title=\"Urban Drainage Software\">Urban Drainage Software<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tThe DREN-URBA\u2019S 2.0 Sewer Pipes Tab\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Inicio","link":"https:\/\/www.hidrasoftware.com\/en\/"},{"label":"Urban Drainage Software","link":"https:\/\/www.hidrasoftware.com\/en\/category\/urban-drainage-software\/"},{"label":"The DREN-URBA\u2019S 2.0 Sewer Pipes Tab","link":"https:\/\/www.hidrasoftware.com\/en\/the-dren-urbas-2-0-sewer-pipes-tab\/"}],"_links":{"self":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/posts\/2872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/comments?post=2872"}],"version-history":[{"count":6,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/posts\/2872\/revisions"}],"predecessor-version":[{"id":7979,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/posts\/2872\/revisions\/7979"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/media\/2873"}],"wp:attachment":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/media?parent=2872"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/categories?post=2872"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/tags?post=2872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}