{"id":2315,"date":"2015-02-02T20:00:36","date_gmt":"2015-02-03T00:30:36","guid":{"rendered":"https:\/\/www.hidrasoftware.com\/?page_id=2315"},"modified":"2025-09-22T15:10:02","modified_gmt":"2025-09-22T15:10:02","slug":"ariete-water-hammer-software","status":"publish","type":"page","link":"https:\/\/www.hidrasoftware.com\/en\/ariete-water-hammer-software\/","title":{"rendered":"Ariete The Easy Water Hammer Software"},"content":{"rendered":"<p><!--StartFragment--><\/p>\n<h1 style=\"\">Do you know how to calculate the Water Hammer?Perform the Basic Analysis with our <strong>Simple Water Hammer Software<\/strong><\/h1>\n<p><!--EndFragment--><\/p>\n<p style=\"\"><!--StartFragment-->Our idea with ARIETE is to offer a basic and sufficient&nbsp;<strong>computer tool<\/strong>&nbsp;so that the majority of the civil engineers can&nbsp;<strong>perform the pipeline<\/strong><strong>\u2019<\/strong><strong>s basic water hammer analyses<\/strong>, without having to resort to more sophisticated and expensive software of which, for sure, they will only use about 50 % of its characteristics.<!--EndFragment--><\/p>\n<h2><!--StartFragment--><!--StartFragment-->Main&nbsp;<strong>Features<\/strong><!--EndFragment--><!--EndFragment--><\/h2>\n<ul>\n<li style=\"\"><span style=\"\"><strong>Generates and Displays the Resulting hydraulic grades envelopes<\/strong> along the pipeline system for various operating conditions.<\/span><\/li>\n<li><span>Models the operation of pumping and gravity pipeline systems.<\/span><\/li>\n<li style=\"\"><span><strong>Allows the visual comparison<\/strong>, on pipeline\u2019s longitudinal profile,&nbsp;<strong>of the maximum hydraulic grade that the piping can withstand<\/strong>, depending on their nominal pressure or pressure rating,&nbsp;<strong>with the resultant ones from different considered operational scenarios<\/strong>, thus determining the sufficiency or not to withstand internal pressures.<\/span><\/li>\n<li style=\"\"><span><strong>Generates the Maximum and Minimum hydraulic grade envelopes<\/strong> under \u201cemergency\u201d conditions, such as the sudden stoppage of pumps in water pumping pipelines.<\/span><\/li>\n<li style=\"\"><span>Evaluates the effect on hydraulic grades and resulting pressure heads when&nbsp;<strong>water hammer control devices, such as one way surge tanks, two way surge tanks, air chambers, bypass lines, flywheels, surge relief valves<\/strong>, among others, are installed in the pipeline.<\/span><\/li>\n<li><span>Makes it possible&nbsp;<strong>to visualize, through customizable charts<\/strong>, the resulting values of pressure and flow (among others) at different points of the pipeline system throughout the simulation time.<\/span><\/li>\n<\/ul>\n<p><span><img decoding=\"async\" alt=\"Ariete-the-easy-water-hammer-software\" data-id=\"2318\" width=\"547\" data-init-width=\"600\" height=\"730\" data-init-height=\"800\" title=\"Ariete-the-easy-water-hammer-software\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/Ariete-the-easy-water-hammer-software.png\" data-width=\"547\" data-height=\"730\" style=\"aspect-ratio: auto 600 \/ 800;\"><\/span><\/p>\n<h5 style=\"text-align: right;\">YOU CAN START USING IT NOW, <strong><span style=\"\">WITHOUT LIMITATIONS!<\/span><\/strong><\/h5>\n<h2 style=\"text-align: center;\"><!--StartFragment--><!--StartFragment--><!--StartFragment--><!--StartFragment-->Why ARIETE <strong>must be among your hydraulic pipeline analysis tools<\/strong>?<!--EndFragment--><!--EndFragment--><!--EndFragment--><!--EndFragment--><\/h2>\n<p><!--StartFragment--><strong>Water Pipeline Design and Analysis<\/strong> involves not only the basic hydraulic designing but also the determination of pressure heads and flows conveyed by the system under different operational conditions, aimed at determining the capacity of the pipeline\u2019s components to withstand the calculated internal pressures in the system.<\/p>\n<p><strong><\/strong>Our&nbsp;<strong>ARIETE Water Hammer Software<\/strong>&nbsp;has been created with the intention of presenting, as explicitly as possible,&nbsp;<strong>the calculation results in the form of a Pipeline\u2019s Longitudinal profile<\/strong> chart and plotting on it the resulting hydraulic grade envelopes in the system for different operating conditions, which range from values resulting in steady state conditions to those obtained under conditions of unsteady flow regime.<\/p>\n<p><!--StartFragment-->Using ARIETE for water hammer calculation is aimed at&nbsp;<strong>studying what the surge pressures generated in the water pipeline system under specific situations are<\/strong>, for example, in a sudden failure of pump equipment and the opening and closing of control valves. It is then possible to evaluate the effect that water hammer control devices, such as&nbsp;<strong>Water Surge Tanks, Air Chambers, Bypass lines, and surge relief valves<\/strong>, among others, would have on the system\u2019s hydraulic response.<!--EndFragment--><\/p>\n<p>In summary, Ariete is a computational tool that&nbsp;<strong>allows the evaluation of different analysis scenarios<\/strong> and, in turn, allows the visual comparison of results for such scenarios so that the civil engineer can achieve better water pipeline designs.<\/p>\n<h2 style=\"text-align: center;\"><!--StartFragment--><!--StartFragment--><!--StartFragment--><!--StartFragment--><!--StartFragment-->Some Screenshots&#8230;<!--EndFragment--><!--EndFragment--><!--EndFragment--><!--EndFragment--><!--EndFragment--><\/h2>\n<p>1<\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>Ariete\u2019s main window shows the pipeline\u2019s longitudinal profile, plotting the calculated and allowable hydraulic grade envelopes:<\/strong><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2323\" width=\"500\" data-init-width=\"900\" height=\"266\" data-init-height=\"479\" title=\"sht03_La Ventana Principal de Ariete, presenta el perfil Longitudinal de la Aduccion en Estudio\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht03_La-Ventana-Principal-de-Ariete-presenta-el-perfil-Longitudinal-de-la-Aduccion-en-Estudio.png\" data-width=\"500\" data-height=\"266\" style=\"aspect-ratio: auto 900 \/ 479;\"><\/span><\/p>\n<p><strong>2<\/strong><\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>You can compare hydraulic grade envelopes for different analysis scenarios:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2321\" width=\"500\" data-init-width=\"900\" height=\"288\" data-init-height=\"519\" title=\"sht01_Es posible Comparar las Piezometricas para Distintos Escenarios\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht01_Es-posible-Comparar-las-Piezometricas-para-Distintos-Escenarios.png\" data-width=\"500\" data-height=\"288\" style=\"aspect-ratio: auto 900 \/ 519;\"><\/span><\/p>\n<p><strong>3<\/strong><\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>In the Pipeline Data dialog, the geometrical and water hammer calculation parameters will be entered:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2322\" width=\"500\" data-init-width=\"901\" height=\"311\" data-init-height=\"561\" title=\"sht02_En los Parametros de Aduccion se Especificaran las propiedades fisicas y de la Simulacion\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht02_En-los-Parametros-de-Aduccion-se-Especificaran-las-propiedades-fisicas-y-de-la-Simulacion.png\" data-width=\"500\" data-height=\"311\" style=\"aspect-ratio: auto 901 \/ 561;\"><\/span><\/p>\n<p>4<\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>You can create libraries of Centrifugal Pumps with different characteristics curves:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2324\" width=\"500\" data-init-width=\"667\" height=\"395\" data-init-height=\"527\" title=\"sht04_Puede Crear Librerias con Curvas Caracteristicas Diferentes para los Equipos de Bombeo\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht04_Puede-Crear-Librerias-con-Curvas-Caracteristicas-Diferentes-para-los-Equipos-de-Bombeo.png\" data-width=\"500\" data-height=\"395\" style=\"aspect-ratio: auto 667 \/ 527;\"><\/span><\/p>\n<p>5<\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>You can include water hammer control devices at the pumping stations\u2019 discharge pipe:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2325\" width=\"500\" data-init-width=\"667\" height=\"395\" data-init-height=\"527\" title=\"sht05_Puedes especificar Dispositivos de Proteccion contra Golpe de Ariete en la Descarga de la Estacion de Bombeo\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht05_Puedes-especificar-Dispositivos-de-Proteccion-contra-Golpe-de-Ariete-en-la-Descarga-de-la-Estacion-de-Bombeo.png\" data-width=\"500\" data-height=\"395\" style=\"aspect-ratio: auto 667 \/ 527;\"><\/span><\/p>\n<p>6<\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>Along the pipeline\u2019s length, it is possible insert water hammer control devices, such as two way surge tanks, among others:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2326\" width=\"500\" data-init-width=\"900\" height=\"333\" data-init-height=\"600\" title=\"sht06_A lo largo de la Aduccion es posible insertar Dispositivos de Proteccion\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht06_A-lo-largo-de-la-Aduccion-es-posible-insertar-Dispositivos-de-Proteccion.png\" data-width=\"500\" data-height=\"333\" style=\"aspect-ratio: auto 900 \/ 600;\"><\/span><\/p>\n<p>7<\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>You can visualize the water hammer calculation results in charts, which you can easily configure to enhance their presentation:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2327\" width=\"500\" data-init-width=\"900\" height=\"351\" data-init-height=\"632\" title=\"sht07_Visualiza los resultados de Presiones y Caudales en Graficos a los cuales\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht07_Visualiza-los-resultados-de-Presiones-y-Caudales-en-Graficos-a-los-cuales.png\" data-width=\"500\" data-height=\"351\" style=\"aspect-ratio: auto 900 \/ 632;\"><\/span><\/p>\n<p>8<\/p>\n<h4><!--StartFragment--><!--StartFragment--><strong>You will be able to generate multiple data series charts in order to compare the selected scenario results:<\/strong><!--EndFragment--><!--EndFragment--><\/h4>\n<p><span><img decoding=\"async\" alt=\"\" data-id=\"2328\" width=\"500\" data-init-width=\"900\" height=\"326\" data-init-height=\"587\" title=\"sht08_Podras presentar y comparar en los graficos los resultados\" loading=\"lazy\" src=\"https:\/\/www.hidrasoftware.com\/wp-content\/uploads\/2015\/02\/sht08_Podras-presentar-y-comparar-en-los-graficos-los-resultados.png\" data-width=\"500\" data-height=\"326\" style=\"aspect-ratio: auto 900 \/ 587;\"><\/span><\/p>\n<h2 style=\"text-align: center;\"><!--StartFragment-->Buy one <strong>Perpetual License<\/strong> Now!<\/h2>\n<h2 style=\"text-align: center;\"><strong><span style=\"color: var(--tcb-tpl-color-12);\">For Only<\/span><\/strong><\/h2>\n<h2 style=\"text-align: center;\"><strong><span><span style=\"color: var(--tcb-tpl-color-12);\">285&nbsp;<\/span><span style=\"font-size: 45px; color: var(--tcb-tpl-color-12);\">\u20ac<\/span><\/span><\/strong><\/h2>\n<h2 style=\"text-align: center;\">Also Available Under Suscription:<\/h2>\n<p><a href=\"#\" style=\"\"><span><span style=\"\"><span>ONE-COMPUTER LICENSE<\/span><\/span><\/span><\/a><a href=\"#\" style=\"overflow: hidden; border-radius: 5px !important;\"><span><span>TWO-COMPUTER LICENSES<\/span><\/span><\/a><\/p>\n<h5><strong>BIANNUAL<\/strong><\/h5>\n<p><em>Install the program on one (1) computer and use it for 6 months<\/em><\/p>\n<p style=\"text-align: right;\"><span style=\"font-family: Yantramanav; font-weight: 400; font-size: 31px; color: rgb(51, 51, 51);\"><\/span><strong><span style=\"color: rgb(33, 193, 123); font-size: 85px;\">114,00<\/span><span style=\"color: rgb(51, 51, 51); font-size: 40px;\">\u20ac<\/span><\/strong><\/p>\n<h5><strong>ANNUAL<\/strong><\/h5>\n<p><em><em>Install the program on one (1) computer and use it for 12 months<\/em><\/em><\/p>\n<p style=\"text-align: right;\"><span style=\"font-family: Yantramanav; font-weight: 400; font-size: 31px; color: rgb(51, 51, 51);\"><\/span><strong><span style=\"color: rgb(255, 255, 255); font-size: 85px;\">171,00<\/span><span style=\"color: rgb(255, 255, 255); font-size: 40px;\"><strong><span>\u20ac<\/span><\/strong><\/span><\/strong><\/p>\n<h5><strong>BIANNUAL<\/strong><\/h5>\n<p><em><em><em><em>Install the program on two (2) computers and use it for 6 months<\/em><\/em><\/em><\/em><\/p>\n<p style=\"text-align: right;\"><strong><span style=\"color: rgb(33, 193, 123); font-size: 85px;\"><span><\/span><strong><span>156,00<\/span><\/strong><\/span><span style=\"color: rgb(33, 193, 123); font-size: 40px;\"><strong><span>\u20ac<\/span><\/strong><\/span><\/strong><\/p>\n<h5><strong>ANNUAL<\/strong><\/h5>\n<p><em><em><em><em><em>Install the program on two (2) computers and use it for 12 months<\/em><\/em><\/em><\/em><\/em><\/p>\n<p style=\"text-align: right;\"><strong><span style=\"color: rgb(255, 255, 255); font-size: 85px;\">214,00<\/span><\/strong><span style=\"color: rgb(51, 51, 51); font-size: 31px;\"><strong><span><strong><span>\u20ac<\/span><\/strong><\/span><\/strong><\/span><\/p>\n<h2><!--StartFragment-->Frequently Asked Questions<\/h2>\n<h4>In Simple Terms: What is Ariete used for?<\/h4>\n<p style=\"\"><!--StartFragment-->The main function sought with Ariete is to <strong>verify the design of water pipeline systems under internal pressures conditions<\/strong>.<\/p>\n<p style=\"\">That is why its main interface presents the analyzed pipeline longitudinal profile, including the envelopes of maximum hydraulic grades that piping components can withstand based on its nominal pressure. Thus,&nbsp;<strong>the user will be able to visually determine, via comparing the resulting envelopes, which pipeline<\/strong><strong>\u2019<\/strong><strong>s sections are at risk of failure<\/strong>&nbsp;when the water hammer phenomena takes place.<\/p>\n<p style=\"\">If you want to see how Ariete allows you to easily detect those pipeline sections that won\u2019t withstand the calculated internal pressures, check out&nbsp;<a href=\"https:\/\/www.hidrasoftware.com\/en\/water-pipeline-design-with-ariete-maximum-allowable-working-pressures\/\" target=\"_blank\">this Tutorial.<\/a><\/p>\n<h4><!--StartFragment-->What Water Hammer Control Devices does Ariete actually include?<!--EndFragment--><\/h4>\n<p style=\"\"><!--StartFragment-->In Ariete\u2019s actual version, it is possible to include the following water hammer control devices:<\/p>\n<ul>\n<li style=\"\">One Way Surge Tank<\/li>\n<li style=\"\">Two Way Surge Tank<\/li>\n<li style=\"\">Surge Relief Valve<\/li>\n<li style=\"\">Air Chamber<\/li>\n<\/ul>\n<p style=\"\"><strong>When the modeled system is a pumping pipeline<\/strong>, it is possible to include at the pumping station\u2019s discharge pipe, the following water hammer control devices:<\/p>\n<ul>\n<li style=\"\">Air Chamber<\/li>\n<li style=\"\">Surge Relief Valve<\/li>\n<li style=\"\">Pumping station\u2019s bypass line.<\/li>\n<li style=\"\">Flywheel (pumping equipment\u2019s rotational inertia increasing)<\/li>\n<\/ul>\n<p style=\"\">Look at&nbsp;<a href=\"https:\/\/www.hidrasoftware.com\/en\/water-hammer-control-devices-incorporated-into-ariete\/\" target=\"_blank\">this Tutorial<\/a> for more information about the Water Hammer control devices included in Ariete.<\/p>\n<h4><!--StartFragment-->What so complicated is the Pipeline System\u2019s Data Introduction in Ariete?<!--EndFragment--><\/h4>\n<p style=\"\"><!--StartFragment-->Our target with Ariete (as well as with our other products in general) is to put within the reach of civil engineers and professionals in the hydraulic area, designing tools that allow them to perform, in a quick and reliable form, the process of designing and making decisions about the need for more complexes calculations (or software).<\/p>\n<p style=\"\">Bearing in mind the previous idea, is that we seek to make the data introduction as practical as possible, so that the complexity is negligible, considering the type of phenomenon that can be analyzed with Ariete (hydraulic transients, water hammer).<\/p>\n<p style=\"\">Specifically, in the case of the data required to perform the water hammer calculation in pipelines, you just need to enter the pipe material, wall thickness, and the number of control points in which the pipeline will be divided.&nbsp;<strong>Leave the rest to Ariete.<\/strong><\/p>\n<p style=\"\">In&nbsp;<a href=\"https:\/\/www.hidrasoftware.com\/en\/creating-the-pipelines-longitudinal-profile-for-water-hammer-calculation-with-ariete\/\" target=\"_blank\">this Tutorial<\/a>, you\u2019ll see how easy is to configure the pipeline data to be ready for water hammer calculation with Ariete.<\/p>\n<h4>What kind of Water Conveyance Systems can I model with Ariete?<\/h4>\n<p style=\"\"><!--StartFragment-->Ariete is oriented to the Design and Evaluation of simple pipeline systems, either operating by gravity or by pumping (gravity or pumping mains). These types of systems have a water source installation at their upstream end (pumping station, reservoir or tank), a main pressurized conveyance pipe, and a receiving water installation (reservoir, tank or valve).<\/p>\n<p style=\"\">A pipeline system in Ariete can be of any length,&nbsp;<strong>but it is only possible, in the current version, to specify a unique pipe\u2019s diameter and material,<\/strong>&nbsp;<strong>and that\u2019s why it does not include special fittings on the line<\/strong> such as tees, wyes, etc.<\/p>\n<h4><!--StartFragment-->On which method for a Pipeline\u2019s Water Hammer Calculation is Ariete based?<!--EndFragment--><\/h4>\n<p style=\"\"><!--StartFragment-->Ariete is based on the well-known&nbsp;<strong>Method of Characteristics.<\/strong><\/p>\n<h4><!--StartFragment-->How do I learn to use it?<!--EndFragment--><\/h4>\n<p style=\"\"><!--StartFragment-->In our blog, you will find a series of&nbsp;<strong>detailed tutorials and several videos,<\/strong>&nbsp;in which you will see not only how Ariete will facilitate and simplify your water pipeline design tasks but also learn to use all its features.&nbsp;<a href=\"https:\/\/www.hidrasoftware.com\/en\/category\/water-hammer\/\" target=\"_blank\">Click here<\/a>&nbsp;to see the list of tutorials.<\/p>\n<p style=\"\"><!--EndFragment-->You can also check out Knowledge Base <a href=\"https:\/\/docs.hidrasoftware.com\/en\/docs\/what-is-ariete\/\" target=\"_blank\">clicking here<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Do you know how to calculate the Water Hammer?Perform the Basic Analysis with our Simple Water Hammer Software Our idea with ARIETE is to offer a basic and sufficient&nbsp;computer tool&nbsp;so that the majority of the civil engineers can&nbsp;perform the pipeline\u2019s basic water hammer analyses, without having to resort to more sophisticated and expensive software of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2315","page","type-page","status-publish","hentry","post-wrapper","thrv_wrapper"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/pages\/2315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/comments?post=2315"}],"version-history":[{"count":34,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/pages\/2315\/revisions"}],"predecessor-version":[{"id":9750,"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/pages\/2315\/revisions\/9750"}],"wp:attachment":[{"href":"https:\/\/www.hidrasoftware.com\/en\/wp-json\/wp\/v2\/media?parent=2315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}